제주대학교 Repository

하수처리장 방류수의 재이용을 위한 2단 PCF/RO 적용에 관한 연구

Metadata Downloads
Alternative Title
A study on the Application of Two Stage PCF/RO for Reuse of Effluent from Sewage Treatment Plant
Abstract
In order to reuse effluent water from Jeju sewage treatment plant, it is necessary to eliminate a highly concentrated Cl- which causes the considerable problems in some areas. Using RO system is considered the best method to get rid of it. As for the pretreatment process, this study is to examine the validity and optimal operating conditions with the fiber filter used in coagulation-sedimentation process. In terms of producing the alternative water resources, this study presented the water quality problems stemming from reuse to understand the reuse potential of the sewage treatment plant(STP) effluent water for agricultural purpose, and also presented the conditions for the stable operation of two-stage PCF/RO that is introduced to solve such problems. In addition, the possibility that the treated water in the two-stage PCF/RO can be used as agricultural water was examined and compared with other standards for overseas and domestic agricultural water. And the following conclusions have been achieved;
1. Based on the results on the optimal condition assessment according to coagulants dosing of two-stage PCF, and waster quality analysis using low SDI15 and COD for fouling prevention, it is determined that 9 ㎖/min dosage is the most stable and effective from the economical aspects depending on filter-run-time
2. Results of the 528 hr operation of two-stage PCF are shown to be adequate for RO pretreatment process because the system did not cause the "breakthrough"effect. Results also indicated the SDI15 below 3.0 and stable treated water, which is appropriate for the application of RO.
3. It is concluded that if the concentration of Cl- and T-N in effluent water is less variable and the target water quality is met, just using two-stage PCF can satisfy the water quality condition for reused water with multi-purpose.
4. Investigation result on adequate treatment when two-stage PCF-treated water was flowed into RO system showed that not only the system was stably operated without any pressure change, but also the excessive Cl- problem that Jeju sewage treatment plant used to have was solved. In addition SS, organic matters, T-N, and T-P, were directly eliminated. Comparison of two-stage PCF/RO treated water quality with standard for domestic and foreign agricultural water resulted in meeting the water quality standards for all analyzed items .
Author(s)
박형건
Issued Date
2008
Awarded Date
2008. 2
Type
Dissertation
URI
http://dcoll.jejunu.ac.kr/jsp/common/DcLoOrgPer.jsp?sItemId=000000004285
Alternative Author(s)
Park, Hyoung-Gun
Affiliation
제주대학교 대학원
Department
대학원 환경공학과
Advisor
이용두
Table Of Contents
Ⅰ. 서론 = 1
Ⅱ. 이론적 고찰 = 4
1. 제주도의 수자원 이용특성 및 하수발생 현황 = 4
1) 용수사용 현황 = 4
2) 하수발생 현황 = 5
2. 하수처리장 방류수 재이용을 위한 처리공정 = 6
1) 응집이론 및 혼화공정의 특성 = 6
2) 여과이론 및 PCF의 특성 = 9
3) 역삼투막의 특성 = 15
3. 경제성분석 = 18
Ⅲ. 실험장치 및 방법 = 20
1. 실험장치 = 20
2. 분석항목 및 방법 = 21
Ⅳ. 결과 및 고찰 = 24
1. 하수처리장 방류수의 수질특성 = 24
1) Cl-농도와 E.C간의 상관성 및 Cl-농도의 추정 = 25
2. 최적 운전조건의 결정 = 27
1) 혼화방식에 따른 처리효율 = 27
2) 응집제 주입량 변화에 따른 수질특성 = 29
3) 역세후 수질 회복 특성과 안정화평가 = 39
4) RO시스템의 적용과 수질특성 = 43
Ⅳ. 결론 = 45
참고문헌 = 47
부록 = 50
Degree
Master
Publisher
제주대학교 대학원
Citation
박형건. (2008). 하수처리장 방류수의 재이용을 위한 2단 PCF/RO 적용에 관한 연구
Appears in Collections:
General Graduate School > Environmental Engineering
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.