제주대학교 Repository

정위적방사선수술에서 다엽콜리메이터 너비의 영향분석

Metadata Downloads
Alternative Title
Impact of Multileaf Collimator Leaf Width on Stereotactic Radiosurgery
Abstract
In this study, we investigated the impacts of multileaf collimator (MLC) width difference in 3D conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) and volumetric intensity modulated arc therapy (VMAT, RapidArc) plan of stereotactic radiosurgery (SRS) for spinal lesions. 19 spinal lesions were retrospectively planned with 3mm MLC and 5mm MLC by both 3DCRT and IMRT. Planning target volume dose coverage, surrounding normal tissue dose sparing, and treatment efficiency were measured and compared each treatment plan. At the last we compared RapidArc plan with other treatment plans which the best plan of them. 3mm MLC system showed advantage in dose coverage of the planning target volume and surrounding normal tissue dose sparing as compared with 5mm MLC system, but there was no statistically significance. IMRT showed advantage in dose coverage of the planning target volume (Target volume coverage 88.68±0.61% vs 84.55±0.88%, p<0.05; Conformity index 1.24±0.05 vs 1.45±0.14, p<0.05) and surrounding normal tissue dose sparing (Dose gradient index 6.98±0.21 vs 7.39±0.25, p>0.05; CV90 0.02±0.01 cm3 vs 0.51±0.12 cm3, p<0.05; CV50 1.00±0.20 cm3 vs 1.61±0.16 cm3, p>0.05) as compared with 3DCRT system, in addition to that, there was statistically significance in parts. RapidArc plan efficiency was more effective than 5mm IMRT system, and was similar to 3mm IMRT system. There was a little difference in dose coverage of the planning target volume by MLC leaf width difference, but to warrant the clinical significant of these results further investigation is needed.
Author(s)
채수민
Issued Date
2011
Awarded Date
2012. 2
Type
Dissertation
URI
http://dcoll.jejunu.ac.kr/jsp/common/DcLoOrgPer.jsp?sItemId=000000005848
Alternative Author(s)
Chae, Soo-Min
Affiliation
제주대학교
Department
대학원 의학과
Advisor
정영배
Table Of Contents
Abstract i
목차 ii
List of Tables iii
List of Figures iv
I. 서론 1
II. 대상 및 방법 4
1. Target Data 4
2. 다엽콜리메이터 4
3. 방사선치료계획 수립 5
4. 평가지표 5
1) 표적선량분포측면 6
2) 주변정상조직보호측면 8
3) 치료계획의 기계적효율성측면 9
5. 통계학적 분석 9
III. 결과 12
1. 표적선량분포측면 12
1) Target volume coverage 12
2) Conformity index 13
2. 주변정상조직보호측면 13
1) Dose gradient index 13
2) 척수보호측면 14
3. 치료계획의 기계적효율성측면 15
IV. 고찰 25
V. 참고문헌 33
Degree
Master
Publisher
제주대학교 대학원
Citation
채수민. (2011). 정위적방사선수술에서 다엽콜리메이터 너비의 영향분석
Appears in Collections:
General Graduate School > Medicine
공개 및 라이선스
  • 공개 구분공개