An experimental study is conducted to develope a horizontal-vertical type underground air picking system. The experiment, which is processed with change of temperature and humidity, conducted to improve effectiveness and to develope a system that will use ground air source and can be applied to horticulture facilities in Jeju Island. Temperature and humidity was adjusted several times during the experiment which was modify underground air conditions.
For the heat pump cycle, multiple evaporators and condensers were used with one compressor in the developed system. While passing several condensers, the temperature of dehumidified underground air which just passed through multiple evaporators rises.
The experiment for the developed heat pump system is conducted in two ways, the series evaporating cycle and the parallel evaporating cycle. The temperature of dehumidified air rose when it passes through the condensers in the experiment of parallel, series evaporating heat pump system.
As results, the heating performance showed about a same level of capacity on average heating system compare to the general unit heaters. However, on the test of series heat pump cycle, the dehumidification did not occur at the third evaporator. In the parallel and series heat pump system, the temperature of air that just completed dehumidification in a evaporator goes up when it passes a condenser. The parallel evaporating heat pump system showed 2.44 in COP, and the series system showed 2.01 which is 18% decreased numerical value compare to parallel one. Also the capability of dehumidification of parallel heat pump cycle was 0.93 kg/kWh, but series cycle had 0.69 kg/kWh. The result indicates that the parallel heat pump cycle system has much efficiency than the series pump system.
Author(s)
고지운
Issued Date
2013
Awarded Date
2013. 2
Type
Dissertation
URI
http://dcoll.jejunu.ac.kr/jsp/common/DcLoOrgPer.jsp?sItemId=000000006282
Alternative Author(s)
Ko,Ji woon
Affiliation
제주대학교 대학원
Department
대학원 기계공학과
Advisor
박윤철
Table Of Contents
Ⅰ. 서 론 1
1.1 연구의 배경 1
1.2 연구동향 및 목적 3
1.2.1 국내 시설원예 히트펌프 기술의 현황 3
1.2.2 연구의 목적 4

Ⅱ. 이론해석 5
2.1 성적계수 5
2.2 냉각 제습능력 6
2.3 습공기의 상태변화 7

Ⅲ. 제주도 지하공기열의 특성 9
3.1 수평형 지하공기 취출시스템 9
3.2 수직형 지하공기 취출시스템 13

Ⅳ. 실험장치 및 실험방법 17
4.1 환경제어설비 17
4.2 히트펌프 시스템 20
4.2.1 병렬증발 히트펌프 시스템 22
4.2.2 직렬증발 히트펌프 시스템 24
4.3 계측장치 26
4.4 실험조건 및 실험방법 29

Ⅴ. 결과 및 고찰 31
5.1 정상상태운전 특성 31
5.2 병렬증발 히트펌프 시스템의 성능특성 34
5.3 직렬증발 히트펌프 시스템의 성능특성 46
5.4 히트펌프 시스템의 제습성능 58

Ⅵ. 결 론 60

참고문헌 62