In order to minimize the lightning damage to wind turbines, lightning
protection strategies for wind turbines from IEC Standard, Europe, USA, Japan
and Korea were reviewed and the strategies available in Korea were proposed
in this work. Also the lightning characteristics of the established and the
scheduled wind farms of Jeju Island as well as entire Jeju Island were
analyzed in detail. The lightning data for 10 years from 2003 to 2012 was
obtained from IMPACT ESP which detects lightning. Lightning frequency,
lightning strength and regional lightning events were analyzed in detail, and
then the lightning maps of Jeju Island were created. The evaluation of
lightning rate was made for all the wind farms of this study. The lightning
damage cases to wind turbines were investigated in the existing wind farms of
Jeju Island. Furthermore, lightning counters were installed in wind turbines to
detect electrical surge by lightning strike. The results obtained are as follows:
First, it is necessary to apply some good lightning protection strategies from
IEC Standard and other countries to Korea. Those are as follows: The
guideline for lightning protection for wind turbines should be established based
on IEC Standards. Both development of software and experimental studies
should be conducted for understanding the types of lightning damage to wind
turbines and compiling the database. For minimizing the lightning damage to
wind turbines, it is a key factor for wind farm owners and researchers to open
the information about the damage cases and wind farm operation technique to
the public.
Second, the eastern part of Jeju Island had more lightning frequency than the
western part of the Island. Also, the evaluation of lightning rate was good for
all the established and the scheduled wind farms of Jeju Island. Hankyung
wind farm is the best place for lightning safety, while precaution should be
taken against lightning damage in Samdal wind farm. There were two
lightning damage reports at Haengwon and Samdal wind farms, which were
the damage to wind turbine blades and the electric device of a turbine.
Finally, the electrical surges were detected in seven wind turbines of Gasi
wind farm by lightning counters. However, the surges were not caused by
lightning strike to the wind turbines.
Author(s)
한지훈
Issued Date
2014
Awarded Date
2015. 2
Type
Dissertation
URI
http://dcoll.jejunu.ac.kr/jsp/common/DcLoOrgPer.jsp?sItemId=000000007051
Department
대학원 풍력특성화협동과정
Table Of Contents
SUMMARY 1
Ⅰ. 서론 2
1. 연구배경 2
2. 연구 목적 5
Ⅱ. 국내·외 풍력발전기에 대한 낙뢰 연구동향 및 적용방안 7
1. 연구동향 8
1) IEC 8
2) 유럽 9
3) 미국 12
4) 일본 15
5) 우리나라 19
2. 적용방안 20
Ⅲ. 제주도의 낙뢰 특성 및 풍력단지의 낙뢰율 22
1. 낙뢰자료 수집 및 연구 방법 22
1) 낙뢰자료 수집 22
2) 분석 범위 및 S/W 25
2. 제주도의 낙뢰 특성 30
1) 낙뢰 특성 30
2) 낙뢰 지도 36
3) 제주도내 풍력단지의 낙뢰율 38
Ⅳ. 풍력발전기에서의 낙뢰 측정 46
1. 낙뢰카운터 설치 46
2. 결과 분석 49
Ⅴ. 결론 54
참고문헌 56
부록 63
Degree
Master
Publisher
제주대학교 대학원
Citation
한지훈. (2014). 風力發電機의 落雷被害對策檢討및 2003-2012年의 濟州地域風力團地의 落雷評價
Appears in Collections:
Interdisciplinary Programs > Multidisciplinary Graduate School Program for Wind Energy
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.