Abstract
Self fire suppression for a nacelle of wind turbine generator system is inevitable because the location of wind farm is generally far from the fire station and the position of the nacelle is too heigh for firefighting equipment to reach it.
The thesis presents a method of early fire detection and fire position determination inside the nacelle. The main variables for fire detection can be illumination, temperature and smoke density, so that the environmental characteristics inside is very important. Thus, we analyzed the characteristics of the nacelle environment that is dependent upon the heat generated by various apparatus of the nacelle and the change of outside environments according to the seasons.
By analyzing the nacelle environment, we found that the absolute values of temperature and smoke density are not suitable as a fire detection variable because they vary depending on seasonal changes. Illumination is also not suitable for fire detection because the absolute value and the rate of change of it is very high, so that it is very difficult to distinguish whether it is fire or not. Therefore, we developed a method of an early fire detection and fire position determination based on the rising rates of temperature and smoke density that are independent from the seasonal changes.
The performance of the method was tested in situation of electric and oil fire that are the most common types of fire inside the nacelle. The results showed that the method is very fast and reliable for fire detection and fire position determination enough to be applied to the actual wind turbine generator system.
Author(s)
김다희
Issued Date
2015
Awarded Date
2015. 8
Type
Dissertation
URI
http://dcoll.jejunu.ac.kr/jsp/common/DcLoOrgPer.jsp?sItemId=000000007305
Alternative Author(s)
Kim, Da hee
Department
대학원 풍력공학과 풍력기계시스템전공
Table Of Contents
I. 서 론 1
1. 연구 배경 1
2. 연구 동향 3
3. 연구 목적 7
II. 나셀 화재 9
1. 화재의 분류 9
2. 나셀 화재 분석 10
III. 나셀 환경 분석 12
1. 나셀 환경 데이터 수집 12
2. 분석 결과 13
1) 조도 분석 결과 13
2) 연기농도 분석 결과 16
3) 온도 분석 결과 18
IV. 화재 감지 21
1. 화재 감지용 센서 특성 21
1) 연기센서 21
2) 온도센서 22
2. 화재 감지 알고리즘 23
1) 화재 감지 변수 선정 23
2) 화재 조기감지 및 위치 판별 25

V. 실험 및 결과 28
1. 화재 감지 시뮬레이터 구성 28
2. 실험과정 32
3. 실험 결과 32
1) 전기화재 실험 결과 32
2) 유류화재 실험 결과 35
3) 종합 결과 38
4. 화재 조기감지 시스템 설계 39
VI. 결 론 43

참고 문헌 45
Degree
Master
Publisher
제주대학교 대학원
Citation
김다희. (2015). 풍력발전시스템 나셀 내부 화재조기감지 및 위치 판별 방법에 관한 연구
Appears in Collections:
Faculty of Wind Energy Engineering > Wind Power Mechanical System Engineering
공개 및 라이선스
  • 공개 구분공개
파일 목록

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.