HVDC 고장감소 및 정비시간 단축을 위한 전력변환 밸브 냉각시스템 개선방안
- Alternative Title
- Improvement of Converter Valve Cooling System for Reducing Fault and Maintenance Time of HVDC
- Abstract
- This dissertation presents the improvement of HVDC thyristor valve cooling system to reduce HVDC fault and its maintenance time. The actual HVDC system is linked between Jeju island and mainland electricity system In case of either HVDC system failure of delay of repair time, power outage brings out not only enormously economic loss but also the significant decrease of the power system stability. Since HVDC convertor valve cooling system is located in confined space, the inspection of cooling system is visually impossible. Therefore, it is important to prevent the failure of valve in advance. In this study, first of all, the failure factors and recovery time in each failure point were analyzed by investigating operation-case of Jeju - Haenam HVDC which has been operating since 1998. Then, the improvement of maintenance for HVDC convertor valve cooling system was proposed by applying the six-sigma technique which currently is a highly recommended quality improvement tool in the industrial sites. Priority, bellows material which is the most frequently defected was improved in order to reduce the failure rate. And then, additional stop valves were placed in the proper position to shorten the maintenance time of failures. Moreover, a demonstration was performed to validate the effectiveness of the proposed improvements. The demonstration proved the significant improvement. It is concluded that the proposed improvements with some modifications possibly apply to cooling system for AD-DC convertor, and it can surely contribute to reliability improvement of HVDC system which currently installed.
- Author(s)
- 송경수
- Issued Date
- 2015
- Awarded Date
- 2015. 8
- Type
- Dissertation
- URI
- http://dcoll.jejunu.ac.kr/jsp/common/DcLoOrgPer.jsp?sItemId=000000007321
- Alternative Author(s)
- Song, Kyoung Soo
- Department
- 산업대학원 전기공학과
- Table Of Contents
- Ⅰ. 서론 1
Ⅱ. HVDC 설비구성 및 냉각시스템 개요 3
2.1. HVDC 설비구성 3
2.2. HVDC 냉각시스템 7
Ⅲ. 냉각시스템 고장원인 및 정비작업 공정 분석 14
3.1. 냉각시스템 고장원인 분석 14
3.2. 냉각시스템 정비작업 공정 분석 및 밸로우즈 성능 점검 17
Ⅳ. 냉각시스템 개선을 위한 잠재요인 분석 21
4.1. 밸브수량과 위치에 따른 점검시간 영향 분석 22
4.2. 냉각수 압력변동과 밸로우즈 불량발생 영향 분석 24
Ⅴ. 냉각시스템 개선 및 검증 25
5.1. 개선안 도출 실험 25
5.2. 개선안 적용 및 검증 26
Ⅵ. 결과 및 고찰 30
Ⅶ. 결론 34
참고문헌 35
- Degree
- Master
- Publisher
- 제주대학교 산업대학원
- Citation
- 송경수. (2015). HVDC 고장감소 및 정비시간 단축을 위한 전력변환 밸브 냉각시스템 개선방안
-
Appears in Collections:
- Graduate School of Industry > Electrical Engineering
- Authorize & License
-
- Files in This Item:
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.