Abstract
The breakthrough in the power and telecommunications industry is an important part of our life culture and should continue to develop. In particular, if part of the high-tech industry stops functioning or accidents such as human casualties, damage to equipment, and malfunction of damage occur, the damage can be seen as an unimaginable disaster. Therefore, major equipment should be prevented from being damaged in advance by high-speed discharge of a strong inrush current from the outside or from the indirect induced brain to the site. However, depending on the geological form, the earth resistance is considerably high and the ground age changes are severe, so a grounding design for securing stable and reliable ground resistance is absolutely necessary. In this paper, the ground design method was discussed in the high resistance zone considering the correction factor. This is an example of securing ground resistance required by applying and analyzing the site resistance data measured in the ground resistance program of Korea Electric Power Corp. by measuring ground resistance using the Wenner 4 electrode method and analyzing the site resistance data measured in the ground resistance support program of Korea Electric Power Corp. and substituting the optimal depth and deep ground resistance to the ground resistance calculation formula, and applying correction factors to the calculated composite resistance if the analyzed in depth of land resistance rate is 500 ohms or higher. In today's era, when planning a grounding design, the ground resistance should be measured several times for the grounding design in order to achieve effective grounding suitable for the grounding purpose, and for securing the required ground resistance rate for the earth-pole system and ground-design site.
Author(s)
고영수
Issued Date
2020
Awarded Date
2020. 8
Type
Dissertation
URI
http://dcoll.jejunu.ac.kr/common/orgView/000000009741
Alternative Author(s)
Ko,Young Su
Affiliation
제주대학교 산업대학원
Department
산업대학원 전기공학과
Advisor
김세호
Table Of Contents
그림 목차 ⅲ
표 목차 ⅳ
SUMMARY ⅴ
1. 서 론 1
2. 일반접지 3
2.1 접지저항 측정방법 3
2.2 대지저항률 측정방법 4
2.3 일반 접지설계 5
3. 고저항 지대의 접지설계 8
3.1 지층구조 8
3.2 대지 저항과 대지 저항률 관계 9
3.3 보정계수를 이용한 접지설계 10
4. 사례연구 17
4.1 지질구조 및 분석 17
4.2 접지설계 및 시공사례 18
4.3 결과 및 고찰 31
5. 결론 32
참 고 문 헌 33